Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Selatan

Bergabung Selama :

BAGIKAN :   

Bagikan :

Hanna HI 9147 Dissolved Oxygen Meter for Aquaculture

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
4 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Hanna HI 9147 Dissolved Oxygen Meter For Aquaculture

Designed specifically for aquaculture Galvanic DO probe Backlit LCD Automatic Temperature Compensation Manual salinity and altitude compensation Water-resistant HI 9147 is designed for aquaculture applications. This unit is unique among our family of DO meters as it is supplied with a galvanic probe. Unlike polarographic probes, galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time, pick it up and measure on demand. HI 9147 is a must have for DO sensitive organisms or high bio-load environments. Order Information: HI 9147-04 is supplied with HI 76409/ 4 probe with 4 m ( 13’ ) cable and spare membranes ( 2) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions. HI 9147-10 is supplied with HI 76409/ 10 probe with 10 m ( 32.8’ ) cable and spare membranes ( 5) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions. HI 9147-15 is supplied with HI 76409/ 15 probe with 15 m ( 49.2’ ) cable and spare membranes ( 5) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions. HI 9147-20 is supplied with HI 76409/ 20 probe with 20 m ( 65.6’ ) cable and spare membranes ( 5) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions. Range O2 0.0 to 50.0 mg/ L ( ppm) % Saturation O2 0 to 600 % Temperature -5.0 to 50.0° C ( 32.0 to 122.0º F) Resolution O2 0.1 mg/ L ( ppm) or 1% Temperature 0.1° C ( 1º F) Accuracy ( @ 20° C) O2 ± 1% of reading Temperature ± 0.2° C ( 1º F) ( excluding probe error) Calibration manual, in saturated air Temperature Compensation automatic, -5 to 50° C ( 23° F to 122° F) Salinity Compensation 0 to 4000 m ( resolution 100 m) Salinity Compensation 0 to 51 g/ L ( ppt) ( 1 g/ L resolution) Battery Type / Life 1.5V AAA ( 3) / approx. 1, 000 hours of continuous use without backlight Environment 0 to 50° C ( 32 to 122° F) ; RH max 95% non-condensing Dimensions 185 x 72 x 36 mm ( 7.3 x 2.8 x 1.4” ) Weight 450 g ( 15.9 oz.) Bebas ongkir untuk daerah jakarta, tanggerang dan sekitar nya Untuk pemesanan produk silahkan hubungi : Nama : Artha Dian E-mail: artha_ global93@ yahoo.co.id Gmail : arthaglobal38@ gmail.com Nomer HP : 081288370803
Tampilkan Lebih Banyak